3.
Environ Sci Technol Lett ; 10(8): 718, 2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37577360

RESUMEN

[This corrects the article DOI: 10.1021/acs.estlett.2c00599.].

6.
Indoor Air ; 32(6): e13064, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35762243

RESUMEN

The exhalation of aerosols during musical performances or rehearsals posed a risk of airborne virus transmission in the COVID-19 pandemic. Previous research studied aerosol plumes by only focusing on one risk factor, either the source strength or convective transport capability. Furthermore, the source strength was characterized by the aerosol concentration and ignored the airflow rate needed for risk analysis in actual musical performances. This study characterizes aerosol plumes that account for both the source strength and convective transport capability by conducting experiments with 18 human subjects. The source strength was characterized by the source aerosol emission rate, defined as the source aerosol concentration multiplied by the source airflow rate (brass 383 particle/s, singing 408 particle/s, and woodwind 480 particle/s). The convective transport capability was characterized by the plume influence distance, defined as the sum of the horizontal jet length and horizontal instrument length (brass 0.6 m, singing 0.6 m and woodwind 0.8 m). Results indicate that woodwind instruments produced the highest risk with approximately 20% higher source aerosol emission rates and 30% higher plume influence distances compared with the average of the same risk indicators for singing and brass instruments. Interestingly, the clarinet performance produced moderate source aerosol concentrations at the instrument's bell, but had the highest source aerosol emission rates due to high source airflow rates. Flute performance generated plumes with the lowest source aerosol emission rates but the highest plume influence distances due to the highest source airflow rate. Notably, these comprehensive results show that the source airflow is a critical component of the risk of airborne disease transmission. The effectiveness of masking and bell covering in reducing aerosol transmission is due to the mitigation of both source aerosol concentrations and plume influence distances. This study also found a musician who generated approximately five times more source aerosol concentrations than those of the other musicians who played the same instrument. Despite voice and brass instruments producing measurably lower average risk, it is possible to have an individual musician produce aerosol plumes with high source strength, resulting in enhanced transmission risk; however, our sample size was too small to make generalizable conclusions regarding the broad musician population.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Aerosoles y Gotitas Respiratorias , Canto , Aerosoles/análisis , Contaminación del Aire Interior/análisis , COVID-19/transmisión , Humanos , Música , Pandemias , Aerosoles y Gotitas Respiratorias/virología
7.
Build Environ ; 219: 109184, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35602249

RESUMEN

The world has faced tremendous challenges during the COVID-19 pandemic since 2020, and effective clean air strategies that mitigate infectious risks indoors have become more essential. In this study, a novel approach based on the Wells-Riley model applied to a multizone building was proposed to simulate exposure to infectious doses in terms of "quanta". This modeling approach quantifies the relative benefits of different risk mitigation strategies so that their effectiveness could be compared. A case study for the US Department of Energy large office prototype building was conducted to illustrate the approach. The infectious risk propagation from the infection source throughout the building was evaluated. Different mitigation strategies were implemented, including increasing outdoor air ventilation rates and adding air-cleaning devices such as Minimum Efficiency Reporting Value (MERV) filters and portable air cleaners (PACs) with HEPA filters in-room/in-duct germicidal ultraviolet (GUV) lights, layering with wearing masks. Results showed that to keep the risk of the infection propagating low the best strategy without universal masking was the operation of in-room GUV or a large industrial-sized PAC; whereas with masking all strategies were acceptable. This study contributes to a better understanding of the airborne transmission risks in multizone, mechanically ventilated buildings and how to reduce infection risk from a public health perspective of different mitigation strategies.

9.
Atmos Environ X ; 13: 100152, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35098105

RESUMEN

Ventilation is of primary concern for maintaining healthy indoor air quality and reducing the spread of airborne infectious disease, including COVID-19. In addition to building-level guidelines, increased attention is being placed on room-level ventilation. However, for many universities and schools, ventilation data on a room-by-room basis are not available for classrooms and other key spaces. We present an overview of approaches for measuring ventilation along with their advantages and disadvantages. We also present data from recent case studies for a variety of institutions across the United States, with various building ages, types, locations, and climates, highlighting their commonalities and differences, and examples of the use of this data to support decision making.

10.
ACS Environ Au ; 1(1): 71-84, 2021 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-37155479

RESUMEN

Outbreaks from choir performances, such as the Skagit Valley Choir, showed that singing brings potential risk of COVID-19 infection. There is less known about the risks of airborne infection from other musical performances, such as playing wind instruments or performing theater. In addition, it is important to understand methods that can be used to reduce infection risk. In this study, we used a variety of methods, including flow visualization, aerosol and CO2 measurements, and computational fluid dynamics (CFD) modeling to understand the different components that can lead to transmission risk from musical performance and risk mitigation. This study was possible because of a partnership across academic departments and institutions and collaboration with the National Federation of State High School Associations and the College Band Directors National Association. The interdisciplinary team enabled us to understand the various aspects of aerosol transmission risk from musical performance and to quickly implement strategies in music classrooms during the COVID-19 pandemic. We found that plumes from musical performance were highly directional, unsteady and varied considerably in time and space. Aerosol number concentration measured at the bell of the clarinet was comparable to that of singing. Face and bell masks attenuated plume velocities and lengths and decreased aerosol concentrations measured in front of the masks. CFD modeling showed differences between indoor and outdoor environments and that the lowest risk of airborne COVID-19 infection occurred at less than 30 min of exposure indoors and less than 60 min outdoors.

11.
Build Environ ; 187: 107368, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33071439

RESUMEN

Various organizations and societies around the globe have issued guidelines in response to the coronavirus disease (COVID-19) and virus (SARS-CoV-2). In this paper, heating, ventilating, and air-conditioning-related guidelines or documents in several major countries and regions have been reviewed and compared, including those issued by the American Society of Heating Refrigerating and Air-Conditioning Engineers, the Federation of European Heating, Ventilation, and Air Conditioning Associations, the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, Architectural Society of China, and the Chinese Institute of Refrigeration. Most terms and suggestions in these guidelines are consistent with each other, although there are some conflicting details, reflecting the underlying uncertainty surrounding the transmission mechanism and characteristics of COVID-19 in buildings. All guidelines emphasize the importance of ventilation, but the specific ventilation rate that can eliminate the risk of transmission of airborne particulate matter has not been established. The most important countermeasure, commonly agreed countermeasures, the conflicting content from different guidelines, and further work have been summarized in this paper.

12.
Am J Infect Control ; 49(4): 438-446, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33022331

RESUMEN

BACKGROUND: Isolation space must be expanded during pandemics involving airborne transmission. Little to no work has been done to establish optimal design strategies and implementation plans to ease surge capacity and expand isolation capacity over long periods in congregate living facilities. The COVID-19 pandemic has an airborne transmission component and requires isolation, which is difficult to accomplish in skilled nursing facilities. METHODS: In this study we designed, implemented, and validated an isolation space at a skilled nursing facility in Lancaster, PA. The overall goal was to minimize disease transmission between residents and staff within the facility. We created an isolation space by modifying an existing HVAC system of the SNF. We measured pressure on-site and performed computational fluid dynamics and Lagrangian particle-based modeling to test containment and possible transmission extent given the isolation space is considered negative rather than individual rooms. RESULTS: Pressure data shows the isolation space maintained an average (standard deviation) hourly value of -2.3 Pa (0.12 Pa) pressure differential between it and the external hallway connected to the rest of the facility. No transmission of SARS-CoV-2 between residents isolated to the space occurred, nor did any transmission to the staff or other residents occur. The isolation space was successfully implemented and, as of writing, continues to be operational through the pandemic. CONCLUSION: Skilled nursing facilities can be retrofitted to provide negative pressure isolation space in a reasonable time frame and a cost effective manner to minimize airborne disease transmission within that space.


Asunto(s)
COVID-19/prevención & control , Aislamiento de Pacientes , SARS-CoV-2 , Instituciones de Cuidados Especializados de Enfermería , Humanos
13.
Indoor Air ; 31(2): 314-323, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32979298

RESUMEN

During the 2020 COVID-19 pandemic, an outbreak occurred following attendance of a symptomatic index case at a weekly rehearsal on 10 March of the Skagit Valley Chorale (SVC). After that rehearsal, 53 members of the SVC among 61 in attendance were confirmed or strongly suspected to have contracted COVID-19 and two died. Transmission by the aerosol route is likely; it appears unlikely that either fomite or ballistic droplet transmission could explain a substantial fraction of the cases. It is vital to identify features of cases such as this to better understand the factors that promote superspreading events. Based on a conditional assumption that transmission during this outbreak was dominated by inhalation of respiratory aerosol generated by one index case, we use the available evidence to infer the emission rate of aerosol infectious quanta. We explore how the risk of infection would vary with several influential factors: ventilation rate, duration of event, and deposition onto surfaces. The results indicate a best-estimate emission rate of 970 ± 390 quanta/h. Infection risk would be reduced by a factor of two by increasing the aerosol loss rate to 5 h-1 and shortening the event duration from 2.5 to 1 h.


Asunto(s)
COVID-19/epidemiología , COVID-19/transmisión , Canto , Ventilación/métodos , Fómites/virología , Humanos , SARS-CoV-2 , Factores de Tiempo , Washingtón/epidemiología
14.
Geohealth ; 4(5): e2019GH000237, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32426622

RESUMEN

Human activities are elevating atmospheric carbon dioxide concentrations to levels unprecedented in human history. The majority of anticipated impacts of anthropogenic CO2 emissions are mediated by climate warming. Recent experimental studies in the fields of indoor air quality and cognitive psychology and neuroscience, however, have revealed significant direct effects of indoor CO2 levels on cognitive function. Here, we shed light on this connection and estimate the impact of continued fossil fuel emissions on human cognition. We conclude that indoor CO2 levels may indeed reach levels harmful to cognition by the end of this century, and the best way to prevent this hidden consequence of climate change is to reduce fossil fuel emissions. Finally, we offer recommendations for a broad, interdisciplinary approach to improving such understanding and prediction.

15.
Environ Health Insights ; 14: 1178630219890876, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32063708

RESUMEN

Volatile organic compounds (VOCs) are emitted from a variety of household and personal care products. Many VOCs are known to be potentially toxic or carcinogenic. Synthetic hair is used in hair-styling practices, including practices in African American communities that involve singeing or heating the synthetic hair. The research questions that we sought to answer were as follows: Are VOCs emitted from singed or heated synthetic hair? If so, what are the VOC species and relative masses identified in singed or heated synthetic hair? We tested samples from 2 sources of singed and heated synthetic hair in a microchamber; one source was flame-retardant synthetic hair and the other source was non-flame-retardant synthetic hair. Our findings confirmed that VOCs are emitted from singed or heated synthetic hair for both types of sources. For flame-retardant synthetic hair, we identified and measured mass for species that included acetone, acetonitrile, 2-butanone, benzene, chloromethane, chloroethane, and 1,2-dichloroethane. For non-flame-retardant synthetic hair, we identified and measured mass for species that included acetone, acetonitrile, chloromethane, trichlorofluoromethane, and 2-propanol.

16.
J Expo Sci Environ Epidemiol ; 30(2): 262-270, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31641277

RESUMEN

Previous research has found increased home ventilation, which may affect health by altering the composition of indoor air, is associated with improvement of respiratory health, but evidence linking home ventilation to objectively measured lung function is sparse. The Colorado Home Energy Efficiency and Respiratory health (CHEER) study, a cross-sectional study of low-income, urban, nonsmoking homes across the Northern Front Range of Colorado, USA, focused on elucidating this link. We used a multipoint depressurization blower door test to measure the air tightness of the homes and calculate the annual average infiltration rate (AAIR). Lung function tests were administered to eligible participants. We analyzed data from 253 participants in 187 homes with two or more acceptable spirometry tests. We used generalized estimating equations to model forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), and FEV1/FVC z-scores as a function of AAIR. AAIRs ranged from 0.10 to 1.98 air changes per hour. Mean z-scores for FEV1, FVC, and FEV1/FVC were -0.57, 0.32, and -0.43, respectively. AAIR was positively associated with increased FEV1/FVC z-scores, such that a 1-unit change in AAIR corresponded to a half of a standard deviation in lung function (ß = 0.51, CI: 0.02-0.99). These associations were strongest for healthy populations and weaker for those with asthma and asthma-like symptoms. AAIR was not associated with FEV1 or FVC. Our study is the first in the United States to link home ventilation by infiltration to objectively measured lung function in low-income, urban households.


Asunto(s)
Contaminación del Aire Interior/estadística & datos numéricos , Pulmón/fisiopatología , Ventilación , Adulto , Asma/fisiopatología , Colorado , Estudios Transversales , Femenino , Volumen Espiratorio Forzado , Humanos , Masculino , Pobreza , Pruebas de Función Respiratoria , Espirometría , Capacidad Vital
17.
Environ Sci Technol ; 53(22): 13053-13063, 2019 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-31652057

RESUMEN

The chemical composition of indoor air at the University of Colorado, Boulder art museum was measured by a suite of gas- and particle-phase instruments. Over 80% of the total observed organic carbon (TOOC) mass (100 µg m-3) consisted of reduced compounds (carbon oxidation state, OSC < -0.5) with high volatility (log10 C* > 7) and low carbon number (nC < 6). The museum TOOC was compared to other indoor and outdoor locations, which increased according to the following trend: remote < rural ≤ urban < indoor ≤ megacity. The museum TOOC was comparable to a university classroom and 3× less than residential environments. Trends in the total reactive flux were remote < indoor < rural < urban < megacity. High volatile organic compound (VOC) concentrations compensated low oxidant concentrations indoors to result in an appreciable reactive flux. Total hydroxyl radical (OH), ozone (O3), nitrate radical (NO3), and chlorine atom (Cl) reactivities for each location followed a similar trend to TOOC. High human occupancy events increased all oxidant reactivities in the museum by 65-125%. The lifetimes of O3, NO3, OH, and Cl reactivities were 13 h, 15 h, 23 days, and 189 days, respectively, corresponding to over 88% of indoor VOC oxidant reactivity being consumed outdoors after ventilation.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Compuestos Orgánicos Volátiles , Carbono , Monitoreo del Ambiente , Humanos , Ventilación
18.
Artículo en Inglés | MEDLINE | ID: mdl-31546585

RESUMEN

Indoor and outdoor number concentrations of fine particulate matter (PM2.5), black carbon (BC), carbon monoxide (CO), and nitrogen dioxide (NO2) were monitored continuously for two to seven days in 28 low-income homes in Denver, Colorado, during the 2016 and 2017 wildfire seasons. In the absence of indoor sources, all outdoor pollutant concentrations were higher than indoors except for CO. Results showed that long-range wildfire plumes elevated median indoor PM2.5 concentrations by up to 4.6 times higher than outdoors. BC, CO, and NO2 mass concentrations were higher indoors in homes closer to roadways compared to those further away. Four of the homes with mechanical ventilation systems had 18% higher indoor/outdoor (I/O) ratios of PM2.5 and 4% higher I/O ratios of BC compared to other homes. Homes with exhaust stove hoods had PM2.5 I/O ratios 49% less than the homes with recirculating hoods and 55% less than the homes with no stove hoods installed. Homes with windows open for more than 12 hours a day during sampling had indoor BC 2.4 times higher than homes with windows closed. This study provides evidence that long-range wildfire plumes, road proximity, and occupant behavior have a combined effect on indoor air quality in low-income homes.


Asunto(s)
Contaminación del Aire/análisis , Monitoreo del Ambiente , Pobreza , Estaciones del Año , Incendios Forestales , Contaminantes Atmosféricos/análisis , Monóxido de Carbono/análisis , Colorado , Humanos , Estudios Longitudinales , Dióxido de Nitrógeno/análisis , Tamaño de la Partícula , Material Particulado/análisis , Hollín/análisis , Emisiones de Vehículos/análisis
19.
Artículo en Inglés | MEDLINE | ID: mdl-30934853

RESUMEN

Consensus is growing on the need to investigate the joint impact of neighborhood-level social factors and environmental hazards on respiratory health. This study used latent profile analysis (LPA) to empirically identify distinct neighborhood subtypes according to a clustering of social factors and environmental hazards, and to examine whether those subtypes are associated with lung function. The study included 182 low-income participants who were enrolled in the Colorado Home Energy Efficiency and Respiratory Health (CHEER) study during the years 2015⁻2017. Distinct neighborhood typologies were identified based on analyses of 632 census tracts in the Denver-Metro and Front Range area of Colorado; neighborhood characteristics used to identify typologies included green space, traffic-related air pollution, violent and property crime, racial/ethnic composition, and socioeconomic status (SES). Generalized estimating equations were used to examine the association between neighborhood typology and lung function. We found four distinct neighborhood typologies and provide evidence that these social and environmental aspects of neighborhoods cluster along lines of advantage/disadvantage. We provide suggestive evidence of a double jeopardy situation where low-income populations living in disadvantaged neighborhoods may have decreased lung function. Using LPA with social and environmental characteristics may help to identify meaningful neighborhood subtypes and inform research on the mechanisms by which neighborhoods influence health.


Asunto(s)
Pulmón/fisiología , Pobreza/estadística & datos numéricos , Características de la Residencia , Población Urbana/estadística & datos numéricos , Contaminación del Aire , Colorado , Crimen , Etnicidad , Humanos , Grupos Raciales , Pruebas de Función Respiratoria
20.
Environ Sci Technol ; 53(9): 4794-4802, 2019 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-30990681

RESUMEN

A 6-week study was conducted at the University of Colorado Art Museum, during which volatile organic compounds (VOCs), carbon dioxide (CO2), ozone (O3), nitric oxide (NO), nitrogen dioxide (NO2), other trace gases, and submicron aerosol were measured continuously. These measurements were then analyzed using a box model to quantify the rates of major processes that transformed the composition of the air. VOC emission factors were quantified for museum occupants and their activities. The deposition of VOCs to surfaces was quantified across a range of VOC saturation vapor concentrations ( C*) and Henry's Law constants ( H) and determined to be a major sink for VOCs with C* < 108 µg m-3 and H > 102 M atm-1. The reaction rates of VOCs with O3, OH radicals, and nitrate (NO3) radicals were quantified, with unsaturated and saturated VOCs having oxidation lifetimes of >5 and >15 h, making deposition to surfaces and ventilation the dominant VOC sinks in the museum. O3 loss rates were quantified inside a museum gallery, where reactions with surfaces, NO, occupants, and NO2 accounted for 62%, 31%, 5%, and 2% of the O3 sink. The measured concentrations of acetic acid, formic acid, NO2, O3, particulate matter, sulfur dioxide, and total VOCs were below the guidelines for museums.


Asunto(s)
Contaminantes Atmosféricos , Ozono , Compuestos Orgánicos Volátiles , Museos , Material Particulado , Universidades